Center pivot efficiency record
A pivot that looks fine from the road can be wasting a fifth of its water, and a few measurements will show where.
Why test a pivot
Center pivots are among the more efficient sprinkler systems, but nozzles wear, regulators fail and pressure drifts. When the pumping plant or nozzle package does not match the design, the result is uneven application, wet and dry rings, and runoff on heavy soils. Testing once a year or after any major repair keeps the system close to its intended performance.
Pressure and flow checks
- Pressure at the pivot point and at the end of the lateral, with a calibrated gauge
- Pressure at several regulators along the lateral
- Flow rate from a flow meter, compared with the design flow
- Pump discharge pressure and total dynamic head
A drop of several pounds per square inch between the pivot point and the end beyond what elevation change explains can point to leaks, clogged nozzles or a failed regulator.
Catch-can uniformity test
Place straight-sided cans in a line from the pivot to the end of the lateral, with spacing set by the test guide. Run the system on a calm day, then measure the depth in each can. Calculate average depth and how far individual cans vary from the average. A coefficient of uniformity in the high 80s or above is usually considered good, and numbers well below that suggest repairs or a revised nozzle package.
Nozzle package inspection
Compare installed nozzles and regulators to the chart for the current pressure and flow. Record the sprinkler type, nozzle size at each outlet, any plugged or missing nozzles and signs of wear. Replace worn nozzles on a schedule, because even small enlargement increases output.
Field observations
Record runoff, ponding, wheel track rutting, crop stress in the corners, wind drift and end gun overthrow. Note the speed setting, percent timer or application depth for each pass.
Seasonal efficiency record
Log water applied by pass, rainfall received, pumping hours, energy used and repairs performed. Divide inches applied by acres to confirm the totals match your meter. Our pump efficiency study connects pressure and energy. Many NRCS offices offer irrigation water management help. For a farm.FM story about what pivots leave undone, see Center Pivot Irrigation Leaves Four Corners to Explain.
Official sources to verify
Confirm rules, dates and fees with the issuing agency before you act.